  d o m e s t i c a i r c o n d i t i o n e r hsu-14hr03/r2 1 . r e a d t h i s m a n u a l c a r e f u l l y t o d i a g n o s e t r o u b l e c o r r e c t l y b e f o r e o f f e r i n g s e r v i c e . 2 . t h i s m a n u a l i s u s e d b y q u a l i f i e d a p p l i a n c e t e c h n i c i a n s o n l y . 3 . h a i e r d o e s n o t a s s u m e a n y r e s p o n s i b i l i t y f o r p r o p e r t y d a m a g e o r p e r s o n a l i n j u r y f o r i m p r o p e r s e r v i c e p r o c e d u r e s d o n e b y o n e u n q u a l i f i e d p e r s o n . c a u t i o n o n / o f f w a l l m o u n t e d t y p e a r c - s e r i e s hsu-18hr03/r2 free datasheet http:///
h su-14hr03/r2 hsu-18hr03/r2 table of contents 1 t a ble of conten t s 1. f eatu res . . ... . . ... 2 2. sp ecifi cation s .. . ..... 3 3. remote controller list s ........ 6 4. sensors list s .......... 6 5. dimensional drawings .. 7 6. operation range .... 9 7. piping di a g rams . ... 10 8. wiring diagram s . 1 1 9. capacit y diagrams and curves diagram s . .. 1 3 10. sound l evel ... 1 7 11. accessorie s .. 1 9 12 . c on tr ol s y stem s .. 20 13 . ce n ter o f g rav i t y .. 21 14. in stall ation s ..2 3 domestic air conditioner
24 hour timer: use the timer function to set on,or off,or from on to off,or from off to on auto restart: the function permits automatic return to previous operation conditions easy clean design: the panel is easy to wash and the airflow vents can be detached without any special tools for quick cleaning of the inside of the air conditioner dry function: make dehumidifying in the room when the unit is working in the "dry" mode sleep mode: the setting temprature and the indoor noise can be adjusted to a more comfortable level when you set the "sleep mode"during night sleep 2 hsu-1 4hr03/r2 hsu-18hr03/r2 features domestic air conditioner auto mode according to the fixed temperature "26 " ,the unit will adjust the operation mode automatically. 1 features
nominalcapacit y and nominal input model norminal ca p acity(3-4) normina l input eer cop energ y label(7-8) annua l energy consumption(9) cooling(1) heating(2) cooling heating cooling heating cooling heating norm. norm. norm norm. kw kw kw kw kwh cooling technica l specific a tions indoor units dimensions weight color sound level f an air fi l ter temper a ture control piping connections(external diameter) insul a tion m a terial hsu-14hr03/r2 unit unit unit sound power(cooling/heating)(6) db(a) db(a) db(a) air flow rate(cooling/heating) high medium low m /min 3 m /min 3 m /min 3 speed(cooling/heating) steps high medium low t ype motor output w liquid gas drain rpm rpm rpm h w d mm mm mm kg mm mm mm heat insulation type 222 265 938 10.6 white 47/47 44 /43 sound pressure (cooling/heating)(5) high medium low 9.1/10 8.0/8.5 1250/1250 950/950 4 1/40 7.2/7.5 4 steps,auto 1150/1150 cross flow fan 30 remote controller removable/washable/mildew proof yr-h10 microcomputer control 6.35 12.7 16 both liquid and gas pipes hig h db(a) hsu-18hr03/r2 specifications 3 domestic air conditioner 4.4 55/55 hsu-14hr03/r2 4.0 1.30 1.28 3.44 3.08 -- -- for indo o r units only: indo o r uni t s coolin g nomina l k w 0.08 nominal input heatin g nominal k w 0.08 hsu-14hr03/r2 1.78 3.09 -- -- 1.66 3.01 hsu-18hr03/r2 5.0 5.5 52/52 51/51 50/50 60/58 10.8/11.3 9.10/9.20 7.8 /8.2 nominal input hsu-18hr03/r2 0.1 0.1 600 725 hsu-18hr03/r2 1350/1350 1250/1250 1100//1100 heat exchanger rows x stages x fin pitch type 2 x 10 x 1.4 ml - 9.52hi - xa bube * this inf ormati on wa s not av ailable at th e time of publication. 2 specifications
technica l specific a tions outdoor units ne t dimensions (stop valve, and bottom support is not included) weight color sound level f an piping connections insul a tion m a terial hsu-14hr03 unit unit sound power(cooling/heating)(6) db(a) db(a) air flow rate(cooling/heating) high low m /min 3 m /min 3 speed(cooling/heating) high low t ype motor output w liquid gas drain rpm rpm h w d mm mm mm kg heat insulation type 540 6 50 245 2 45 780 780 44 45 sound pressure(cooling/heating)(5) high high 36/34 --- 850 --- propeller fan 19 6.35 12.7 16 both liquid and gas pipes white 5 5/54 64 /65 refrigeran t circuit refrigerant type refrigerant charge maximum allowable distance between indoor and outdoo r maximum allowable level di f ference refrigerant control kg m m compressor t ype model toshiba pa160x2c-4ft hitachi ash201sv-c8lu motor output oil type equivalent esteroil vg74 oil charge volume l mm mm mm unit r410a 1.10 20 15 w 1350 1650 0.48 0.6 hsu-14hr03/r2 specifications 4 domestic air conditioner rotary compressor /r2 hsu-18hr03/r2 60/58 67/68 36/34 --- --- 850 r410a 1.35 15 20 --- hsu-18hr03/r2 heat exchanger type rows x stages x fin pitch 2 x 10 x 1.4 ml - 9.52hi - xa bube f o r c omb i n a t i o n ind o o r u n i t s + o u t d o o r u n i t s : c ool i n g a nomi n a l running current heating a c ool i n g a max i m u m running current h e a t i n g a c ool i n g a curre n t sta r ting current h e a t i n g a 5.9 5.8 7.5 8.2 hsu-14hr03/r2 hsu-18hr03/r2 8.0 10.0 7.5 9.0 39 39 39 39 electrical specifications
hsu-14hr03/r2 hsu-18hr03/r2 specifications 5 domestic air conditioner f o r i n d o o r u n i t s o n l y : p o w e r s u p p l y v m v m p h a s e f r e q u e n c y h z 5 0 5 0 nominal distrib u tion sys t e m v o l t a g e v o l t a g e v 230 n o t e s 1 nominal cooling capacities are based on: indoor temperature 27cdb/19cwb * outdoor temperature 35cdb * refrigerant piping length: 5m * level di f ference: 0m. 2 nominal heating capacities are based on: indoor temperature 20cdb * outdoor temperature 7cdb/6cwb * refrigerant piping length 5m (horizontal) * level di f ference 0m. 3 capacities are net, including a deduction for cooling (an additi on for heating) for indoor fan motor heat. 4 units should be selected on nominal capacit y . maximum capacity is limited to peak periods. 5 6 the sound power level is an absolute value indicating the powe r which a sound source generates. 7 energy label: scale from a (most e f ficient) to g (less e f ficient). 8 the energy label directive 2002/31/ec will enter into force o n ce the relevant measurement standard will be published in the european o f ficial standard. 9 annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions) 1 p h 1 p h 2 30 hsu-14hr03/r2 hsu-18hr03/r2 t h e s o u n d p r e s s u r e l e v e l i s m e a s u r e d i n a n a n e c h oi c r o o m a t 1 m d i s t a n c e f r o m t h e u ni t . i t i s a r e l a t i v e v a l u e , d e p e n d i n g o n t h e d i s t a n c e a n d a c o u s t i c e n v i r on m e n t . f o r m e a s u r i n g c o n d i t i o n s : p l e a s e r e f e r t o i t e m 8 o f t h i s c h a p t e r .
model hsu-1 4hr03/r2 yr-h10 y 6 hsu-18h r 03 /r2 y hsu-1 4 h r03/r2 hsu-18h r 03 /r 2 remote controller&sensors domestic air conditioner 3 remote controller list s 4 sensors list s i n d o o r u n i t t y pe d e s c r i p t i o n q t y r o o m s e n s o r it's used for de t e c ting room tem p erature 1 p i p e s e n s o r i t 's used f or de t e c t ing t empera t u r e of evapora t o r 1
hsu-14hr03/r2 hsu-18hr03/r2 dimensional drawings 7 domestic air conditioner hsu-14hr03/r2 indoor unit hsu-14hr03/r2 outdoor unit rear the mark show the piping direction rear t he airflow direction right left 5 dimensional drawings 2-way valve 6.35mm(1/4") 3-way valve 12.7mm(1/2") 222
hsu-14hr03/r2 hsu-18hr03/r2 dimensional drawings 8 domestic air conditioner hsu-18hr03/r2 indoor unit hsu-18hr03/r2 outdoor unit rear the mark show the piping direction rear t he airflow direction right left dimensional drawings 222
9 hsu-14hr 03/r2 hsu-18hr03/r2 operation range domestic air conditioner cooling 50 the name of parts d b 46 40 43 nwodllup 03 20 18 10 0 16 23 32 10 20 30 indoor temp wb o u t d o o r t e m p . 25 gnitaeh 42 20 o u t d o o r t e m p bw 15 10 5 0 -5 -10 -15 10 20 30 indoor temp db notes the graphs are based on the following condition equivalent piping length 7.5m level difference 0m air flow rate high o u t d o o r t e m p -7 6 operation range
7 7 p p i i p p i i n n g g d d i i a a g g r r a a m m s s piping diagrams hsu-14hr03/r2 hsu-18hr03/r2 10 domestic air conditioner capillary tub e che c k v al v e gas stop valv e lquid stop valv e reversing valve compresso r outdoor fan moto r propeller fa n cross flow fa n r e g n a h c x e t a e h r o o d t u o r e g n a h c x e t a e h r o o d n i indoor fan moto r air outlet air outlet cooling operation heating operation hsu-18hr03/r2 capillary tube check valve gas stop valve lquid stop valve reversing valve compressor outdoor fan motor propeller fan cross flow fan regnahcxe taeh roodtuo regnahcxe taeh roodni indoor fan motor air outlet air outlet cooling operation heating operation hsu-14hr03/r2
hsu-14hr03 /r2 hsu-18hr03/r2 wiring diagrams domestic air conditioner 8 8 w wi ir ri in ng g d di ia ag gr ra am ms s hsu-14 hr03/r2 hsu-18 hr03/r2 indoor u n it c u r r e n t c n 8 indoo r wir ing di agram n ote : 2.c ool ing onl y 1.h eat pu mp po we r su pply 1p h, 220 v~,50hz i o n g e n e r a t o r b b r b r r c 1 w c 2 b b l l w n b r trans former r c n 3 c n 2 b l b l c n 1 c n 7 c n 9 r r w 1( l) 2 (n) b b r 3 4 t e r m i n a l 0 0 1 0 5 4 1 7 8 2 a mbient temp. sensor @ r lo uver mo tor @ b r pi ping t emp.se nsor c n 6 1 (l) w 2( n) b emerg ency sw itch c n 5 s 9 0 1 gignal m o t o r f a n b r 4 3 @ @ t e r m i n a l 3. ion ge ner ator no dot ted li nes ,ma rked wi th @ 1 conn ect ing wi re is s how n a bov e (in clu din g d ott ed l ine s) 1 f c 1 f u s e t 3 . 1 5 a / 2 5 0 v a c t e s t no co m receiv er bo ard the par t is op tio nal b l : b l u e y /g: ye llo w/g reen b r: bro wn g: g reen r: red w: whit e b: black y/ g y/g y / g y/ g y/ g y/ g m m lock c at c h locking s tructure remova l of locking te rminal contact so me terminal con tact(as shown th e locking and p ull f ront lever to r elease pleas e press the the cable out. in t he figure) comes with 11
hsu-14hr03 /r2 hsu-18hr03/r2 wiring diagrams domestic air conditioner outdoor unit hsu-14hr03/r2 hsu-18 hr03/r2 12
indoor temp. db/wb 18 20 25 32 35 40 43 46 18/12 2568 2579 2591 2353 2364 2410 2249 2124 18/14 3086 3099 3170 2900 2860 2720 2600 2508 20/15 3604 3618 3632 3530 3357 3183 3037 2891 22/16 3547 3564 3581 3508 3321 3100 2950 2880 25/18 3489 3510 3530 3486 3286 3085 2953 2850 27/19 3769 3672 3726 3551 3436 3280 3148 3015 30/22 3857 3807 3759 3742 3655 3515 3330 3280 32/23 3985 3891 3800 3763 3702 3585 3447 3309 32/24 4000 3970 3875 3840 3778 3658 3518 3377 outdoor temp.(humidity 46%) cooling value-temerature talbe hsu-14hr03/r2performance curves cooling value-temp.curves 1000 1500 2000 2500 3000 3500 4000 4500 5000 18 / 12 18 / 14 20 / 15 22 / 16 25 / 18 27 / 19 30 / 22 32 / 23 32 / 24 indoor tempe.(db/wb) conoling capacity(w) 18 20 25 32 35 40 43 46 hsu- 14hr 03 /r2 hsu-18hr03/r2 wiring diagrams 13 domestic air conditioner
outdoor temp. db/wb 15 20 25 -15 2011 1943 1853 -5 2790 2710 2596 5 2912 3078 2962 7/6 3640 3548 3203 15 4400 4340 3890 20 4287 4073 3664 25 3944 3847 3571 indoor temp.(humidity 46%) heating capacity and indoor/outdoor temp.curves hsu-14hr03/r2 performance curves heating capacity and indoor/outdoor temp.curves 1000 1500 2000 2500 3000 3500 4000 4500 5000 -15 -5 5 7/6 15 20 25 indoor tempe.(db/wb) conoling capacity(w ) 15 20 25 14 domestic air conditioner hsu-14hr03 /r2 hsu-18hr03/r2 wiring diagrams
indoo r tem p . db/ w b 16 2 0 2 5 3 2 3 5 4 0 4 3 4 6 18/12 33 9 5 33 6 2 32 6 3 31 9 6 28 9 8 25 8 7 23 3 4 22 3 4 18/14 36 7 6 35 7 2 34 6 6 33 9 5 30 0 3 27 6 9 24 7 8 23 7 2 20/15 37 8 4 36 8 1 35 7 2 34 9 9 31 7 2 29 0 7 25 5 3 24 4 4 22/16 40 3 6 38 0 6 37 4 2 36 1 8 32 7 9 30 3 5 26 3 9 24 6 4 25/18 42 6 0 39 8 9 38 7 1 37 9 2 34 3 6 32 3 5 27 6 4 25 3 5 27/19 44 8 2 41 1 4 39 8 4 39 0 2 36 5 9 35 0 0 31 1 1 27 2 2 30/22 47 6 7 44 9 3 42 2 9 41 4 3 38 7 7 36 9 2 32 8 3 28 8 9 32/23 48 2 1 46 5 3 44 4 7 43 5 6 39 4 7 36 6 6 33 4 0 30 3 6 32/24 49 8 4 47 2 2 45 0 4 43 9 1 39 2 2 36 3 7 33 9 7 31 8 1 outdoor temp.(humidity 46%) cooling capaci t y and indoor / ou t door t emp . curves hsu-18hr03/r2 performance curves cooling value- t emp . curves 20 0 0 22 0 0 24 0 0 26 0 0 28 0 0 30 0 0 32 0 0 34 0 0 36 0 0 38 0 0 40 0 0 42 0 0 44 0 0 46 0 0 48 0 0 50 0 0 52 0 0 8 1 2 1 / 8 1 4 1 / 0 2 5 1 / 2 2 6 1 / 5 2 8 1 / 7 2 9 1 / 0 3 2 2 / 2 3 3 2 / 2 3 4 2 / indoor temp.(db/wb) ) w ( y t i c a p a c g n i l o o c 1 8 2 0 2 5 3 2 3 5 4 0 4 3 4 6 hsu-14hr03/r2 hsu-18hr03/r2 capacity 15 domestic air conditioner
outdoor temp . db/w b 20 / 1 5 20/14.5 20 / 1 2 27 / 1 8 - 5 399 2 392 9 374 2 335 0 0 438 8 412 9 407 5 365 8 5 460 4 434 5 426 1 383 6 7/6 500 2 455 0 448 6 419 5 1 0 527 6 496 6 476 0 438 4 1 5 532 9 510 3 498 6 442 7 2 4 538 5 513 2 493 7 446 6 indoor t emp . (humidi t y 46%) hsu-18h r03/r2 performance curves heating capacity and indoor/outdoor temp.curve s heating capacity and indoor/outdoor temp.curves heating capacity(w) 20/15 20 /14 .5 20/12 27/18 16 domestic air conditioner hsu-14hr03/r2 hsu-18hr03/r2 capacity
17 hsu-14hr03 /r2 hsu-18hr03/r2 accessories domestic air conditioner hsu-14hr03/r2 hsu-18hr03/r2 44.2/42.0 46.2/44.3 42.1/40.2 44.1/41.7 40.5/37.5 54.7/54.9 57.0/58.3 36.9/33.8 model sound presure level 230v,50hz cooling/heating measuring location sound power level (cooling/heating) h l sl location of microphone 10 sound level hsu-14hr03/r2 indoor outdoor
18 hsu-14hr03 /r2 hsu-18hr03/r2 accessories domestic air conditioner octave band center frequency(hz) approximate threshold hearing for continuous noise heating cooling 63 125 250 500 1000 2000 4000 8000 20 30 40 50 60 70 80 53 106 212 425 850 1700 3400 6800 nc-70 nc-60 nc-50 nc-40 nc-30 nc-20 indoor outdoor octave band center frequency(hz) approximate threshold hearing for continuous noise 63 125 250 500 1000 2000 4000 8000 20 30 40 50 60 70 80 53 106 212 425 850 1700 3400 6800 nc-70 nc-60 nc-50 nc-40 nc-30 nc-20 sound level hsu-18hr03/r2
19 hsu-14hr03/r2 hsu-18h r03/r2 accessories domestic air conditioner standard name hsu-14hr03/r2 drain hose 1 plastic bag remote controller 1 1 air purifier2 hsu-18hr03/r2 1 1 1 2 battery 2 2 mounting plate 1 1 1 1 screw assembly installation manual operation manual 1 1 1 1 11 accessories
20 hsu-14hr03/r2 hsu-18hr03/r2 control systems domestic air conditioner hints after replacing with new batteries, remote controller will conduct self-check, displaying all information on lcd. then, it will become normal. clock set when unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: press clock button, "am" or "pm" flashes. press or to set correct time. each press will increase or decrease 1min. if the button is kept depressed, time will change quickly. after time setting is confirmed, press set, "am "and "pm" stop flashing, while clock starts working. note:(1)the following functions and related displays are not available: auxiliary heat display, power/soft display,health display. (2)if the air conditioner don't have the function of the code ,press code b can cause it not available. (3)cooling only unit do not have functions and displays related with heating. buttons and display of the remote controller. if the unit which you purchased has not health function, remote controller should like the following figure: 1.mode display auto cool dry heat fan 2. swing display 3. fan speed display 4. health display 5. sleep display 6. lock display 7. timer on display 8. auxiliary heat display 9. swing 10. mode used to select auto,cool and fan 11. clock used to set correct time 12. timer used to select timer on,timer off 13. reset used to reset the controller back to normal condition. 14. code used to select code a or b with a press,a or b will be displayed on lcd.please select a without special explanation 15. code display 16. signal sending display 17. power/soft display 18. temp. display 19. clock display 20. timer off display 21. temp used to select your desired temperature 22. fan used to select fan speed 23. power on/off used for unit start or stop 24. sleep used to select sleep mode 25. set used to confirm timer and clock settings 26. hour used to set clock and timer settings 27.lock used to lock buttons and lcd display. auto lo med hi
domestic air conditioner hsu-14hr03/r2 hsu-18hr03/r2 center of gravity 21 13 center of gravity outdoor unit indoor unit hsu-14hr03/r2
domestic air conditioner hsu-14hr03/r2 hsu-18hr03/r2 center of gravity 22 center of gravity indoor unit hsu-18hr03/r2
hsu-14hr03/r2 hsu-18hr03/r2 installation 14 installation indoor the mounting plate should be installed on a wall which can support the weight of the indoor unit . piping hole pipe how to attach the indoor unit. hook the claws of the bottom frame to the mounting plate . if the claws are difficult to hook ,remove the front panel . how to remove the indoor unit. push up the marked area (at the lower part of the front panel ) to release the the claws . if it is difficult to release ,remove the front panel . cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipes cut line . air filter open the inlet g r ille b y pulling it up w ard. how to attach the air filter. close the inlet g r ill e . push up the filter's center tab slightly until it is released from the stopper, and rem o v e the filter d o wn w ard. attach the filter correctly so that the "f r ont" indication is f acing to the front.ma k e sure that the filter is completely fi x ed behind the stopper.if the r ight and left filters are not attached correctl y , that m a y cause de f ect s . how to rem o v e the air filter. bottom frame mounting plate claws service lid the service lid is an open/close type remove the screws on the service lid. slide the service lid leftward. rotate the service lid upward 23 domestic air conditioner
500 140 140 6 5 2 w rap the installation pipe with the finishing tape from bottom to top model 35 / 40 class service lid how to remove the service lid. this service lid is an open/close type. slide the lid downward to remove it. how to attach the service lid. insert the upper part of the service lid into the outdoor unit to install. t ighten the screws. ar r angement of piping directions rear left rear r ight left bel o w right outdoor unit the distance between the indoor unit and the floor should be more than 2m fix the unit to concrete or block with bolts( 10mm) and nuts f irmly and horizontall y . when fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind. if vibration may a f fect the house, fix the unit by attaching a vibration-proof mat. where there is a danger of the unit falling, use foot bolts, or wires. model 35/40 class max.allowable length cooling only 20m heat pump 25m max.allowable height 15m additional refrigerant required for refrigerant pipe exceeding 5m in length 20g/m gas pipe liquid pipe o.d. 12.7 o.d. 6.35 m c 0 1 n a h t e r o m m c 0 1 n a h t e r o m i n st alla t i o n s 2 4 dome st i c a ir condi t i o n hsu-1 4hr 03 /r2 hsu-18hr03/r2 *be sure to add the proper amount of additional refrigerant. failure to do so may result inreduced performance.
hsu-14hr 03/r2 hsu-18hr03/r2 the end 25 domestic air conditioner sincere forever haier group haier industrial park, no.1, haier road edited by: 266101, qingdao, china e-mail: hractech@haier.com signed by: t el: +86 532 87636957 http://ww w .haie r .com approved by: ma sai zhang lizhi zhu zhenxue


▲Up To Search▲   

 
Price & Availability of HSU-14HR03R2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X